AM/FM Monitor Cable Fault Locator
AM/FM Generate Frequency Counter
Audio Synthesizer Digital Voltmeter
Spectrum Analyzer Wattmeter
Duplex Generator Oscilloscope
Sweep Generator Signal Strength Meter
Tracking Generator SINAD/Distortion Meter
FREQUENCY
Range: 400 kHz to 1 GHz
Resolution: 50 Hz
Accuracy: Refer to Accuracy of Master Oscillator
Stabilization Time: .1 Second
OUTPUT
Range FM: -130 dBm to 0 dBm
Range AM: -130 dBm to -3 dBm
Accuracy: ±2 dB, -80 dBm to -130 dBM, RF I/O Port
±4 dB, >3 MHz, all other levels and ports.
SWEEP GENERATOR
Range: 400 kHz to 1 GHz
Resolution: 50 Hz
Output: -130 dBm to 0 dBm
Sweep Width: Selectable up to ±5 MHz of center freq.
Scope Coupling: Synchronized scope trace to the
sweep signal
Accuracy: Same as Signal Generator
DUPLEX GENERATOR
Range: 400 kHz to 1 GHz
Receiver Resolution: 50 Hz
Output: -130 dBm to 0 dBm
Frequency Offset 0 MHz to ±999.995 MHz in 5 kHz steps
Accuracy: Same as Signal Generator
SPECTRAL PURITY
Spurious: -35 dBc within ±20 MHz of selected
carrier frequency. Additional fixed
spurs at an absolute level of <-90 dBm
at harmonic frequencies of 5 MHz.
These can affect level and modulation
measurements when operated at low
levels at or very near these specific
frequencies.)
Harmonics: -20 dBc
FM MODULATION
Deviation: 99.5 kHz
Accuracy: 5% of setting ±25 Hz @ 1 kHz (NB)
5% of setting ±250 Hz @ 1 kHz (WB)
Residual FM: 20 Hz max @ 300 Hz to 3 kHz
Frequency Range:5 Hz to 20 kHz
AM MODULATION
Range: 0 to 90%
Resolution: 1% of modulation
Residual AM: 1.0% max @ 300 to 3 kHz
Frequency Range: 100 Hz to 10 kHz
PHASE MODULATION (Optional)
Range: 0.5 to 10 radians
Accuracy: ±8% at 1 kHz
Resolution: .1 radians (.01 below 2.00 radians)
Frequency Range: 300 to 3000 Hz
Audio Modulation Synthesizer (Cont.)
External Modulation
Inputs: Front panel microphone and a BNC
jack are summed.
BNC Input Impedance: 600 ohms nominal
Microphone Supplied: HMN-1056D
Microphone Input
Conditioning: Internal audio limiting providing IDC
and pre-emphasis.
FREQUENCY
Range: 400 kHz to 1 GHz
Resolution: 50 Hz
Accuracy: Refer to Accuracy of Master Oscillator
Spurious Response: 40 dB typical
SENSITIVITY
(Above 10 MHz)
Narrowband FM: 2.0 uV for 10 dB EIA SINAD
Wideband FM: 10 uV for 10 dB EIA SINAD
AM: 10 uV for 10 dB EIA SINAD
FREQUENCY ERROR
METER
Type of Display: Autoranging
Resolution: 1 Hz
FM DEVIATION
MEASUREMENT
Demod Range: Up to ±5 kHz in Narrowband
Up to ±75 kHz in Wideband
Accuracy: ±5% plus peak residual FM
Frequency
Response: Selectable per the following:
Low Pass Filters
300 Hz, 3 kHz, 20 kHz
High Pass Filters
5 Hz, 300 Hz, 3 kHz
Demodulated
Output Level: 0.8 V peak per 1 kHz peak Deviation in
Narrowband and per 10 kHz
Deviation in Wideband
Demodulation
Output Impedance: 100 ohms nominal
Deviation Alarm: Audible, set via keypad in 100 Hz
increments
AM MODULATION
MEASUREMENTS
Demodulation
Range: 0 to 100%
Accuracy: ±5% for levels below 80%
Frequency Response: Selectable per the following:
Low Pass Filters
300 Hz, 3 kHz, 20 kHz
High Pass Filters
5 Hz, 300 Hz, 3 kHz
Demodulated
Output Level: 0.8 V peak per 10% AM modulation
Output Impedance: 100 ohms nominal
PHASE
DEMODULATION
MEASUREMENTS (Optional)
Demod Range: Narrowband = 1 radian
Wideband = 10 radians
Accuracy/
Frequency Response: ±5% at 1 kHz, ±7.5% 300 Hz to 3.5 kHz with
de-emphasis filter cornered at 100 Hz
Output Impedance: 100 ohms nominal
Modulation Types: 1 kHz tone, PRIVATE LINE, DIGITAL
PRIVATE LINE, Single Tone, DTMF,
Two-Tone Paging, 5/6 Tone Paging,
International Select V, 20 Tone General
Sequence, Tone Remote Control,
External inputs from both a supplied
microphone and BNC input.
Mod Output
Amplitude Flatness: 5 Hz to 20 kHz ± 1 dB
Mod Output Level: Programmable to ± 7.95 v peak
Mod Output
Impedance: 100 ohms nominal
1 kHz Tone Distortion: Not to exceed 1% THD
12
Signaling Types: SMARTNET, SmartZone (Type I,
Type I EP II, Type II), ASTRO (VSELP/IMBE).
ASTRO testing in the Trunked mode is
limited to functional verification of
operation on a traffic channel. More
detailed testing of Data, BER and
Encryption are done in conventional mode
through use of the ASTRO diagnostic
options.
Call Sequence Tests: Dispatch
Phone Interconnect
Call Alert
Failsoft
TRUNKING (OPTIONAL FEATURE)
OPERATING/DISPLAY MODES
RF SIGNAL GENERATOR
AUDIO MODULATION SYNTHESIZER
RF RECEIVER
Komentarze do niniejszej Instrukcji